Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Braz. oral res. (Online) ; 36: e053, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1374749

ABSTRACT

Abstract: This study assessed the ability of XP-endo Finisher R (FKG, La Chaux-de-Fonds, Switzerland) to remove filling remnants from curved mesiobuccal canals of maxillary molars, using the passive ultrasonic irrigation (PUI) technique as a comparison. Twenty-four curved main mesiobuccal canals (MB1) of maxillary molars were instrumented with Wave One (#25/07) and filled with gutta-percha points and AH Plus Sealer. Samples were then re-treated with a standardized protocol with Wave One (#35/06) as the master apical file. Micro-CT scans measured baseline volume of remaining filling material (in mm3). Samples were divided into two groups (n = 12) according to the supplementary cleaning approach: (PUI) or XP-endo Finisher R. Statistics compared baseline and final volume of filling material (within-group); and the percentage of filling material reduction (between-group). Mean baseline volumes, final volumes, and percentages of reduction (%) of filling material for XP-endo Finisher R and PUI were respectively: 0.060 mm3, 0.042 mm3, and 31.28%; and 0.064 mm3, 0.054 mm3, and 16.57%. Both tested protocols reduced the amount of filling material (p < 0.05). XP-endo Finisher R had higher percentage of reduction as compared to PUI (p < 0.05). XP-endo Finisher R and PUI used as supplementary cleaning protocols during re-treatment improved the removal of root filling material in curved canals; but XP-endo Finisher R was approximately twice more efficient. The complete filling material removal during re-treatment procedures is still a challenge. Supplementary cleaning protocols may help to remove the remaining material after the complete mechanical preparation of curved canals. XP-endo Finisher R was approximately twice more efficient than PUI.

2.
Braz. dent. j ; 32(4): 1-7, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345516

ABSTRACT

Abstract This study evaluated the 3D quality of root-end filling, assessing the presence (volume and percentage) of marginal gaps and internal voids formed after retro-filling with three calcium silicate-based materials: MTA Angelus (Angelus Soluçoes Odontologicas, Londrina, PR, Brazil), Biodentine (Septodont Ltd., Saint Maur-des-Faussés, France) and Neo MTA Plus (Avalon Biomed Inc., Bradenton, Florida, US). Thirty human, extracted, single rooted teeth were used. Orthograde root canal treatment, root resection (3mm shorter than the apex) and retrograde cavity preparation with ultrasonic tips were performed. Teeth were divided into 3 groups (n =10 each) following a stratified randomization according to the initial volume of the root-end cavity. After retrofilling, samples were stored for 7 days. Then, two rounds of micro-CT scans were performed: soon after root-end preparation (with the cavity still empty) and 7 days after root-end filling. Marginal gaps, internal voids volume (mm3 and %), as well as, the overall defects (sum of gaps and voids) were evaluated. Statistics compared the three groups in relation to those defects. There was not statistical difference between groups regarding the marginal gaps (P≥ 0.05), the internal voids (P≥ 0.05), and the overall defects (P≥ 0.05). Median (mm3) and % of overall air-entrapment defects (gaps and/or voids) was: 0.004mm3 and 1.749% for MTA Angelus, 0.018mm3 and 6.660% for Biodentine, and 0.012mm3 and 4.079% for Neo MTA Plus. All materials had gaps and/or voids. No differences were found between MTA Angelus, Biodentine and Neo MTA Plus.


Resumo Este estudo avaliou a qualidade 3D de retro-obturações, avaliando a presença (volume e percentagem) de "gaps" marginais e "voids" internos formados a partir da retro-obturação com três materiais à base de silicato de cálcio: MTA Angelus (Angelus Soluções Odontológicas, Londrina, PR, Brasil), Biodentine (Septodont Ltd., Saint Maur-des-Faussés, França) and Neo MTA Plus (Avalon Biomed Inc., Bradenton, Flórida, US). Trinta dentes humanos unirradiculares extraídos foram usados. Após tratamento de canal ortrógrado, resecção radicular (3 mm apicais), o prepare da cavidade retrógrada com pontas ultrassônicas foi realizado. Os dentes foram divididos em três grupos (n= 10 cada) seguindo uma randomização estratificada, de acordo com o volume inicial da cavidade retrógrada. Depois da retro-obturação as amostras foram armazenadas por 7 dias. Duas rodadas de escaneamento de micro-CT foram realizadas: logo após o preparo retrógrado (com a cavidade ainda vazia) e 7 dias após a retro-obturação. O volume de "gaps" marginais e de "voids" internos (mm3 e %), bem como, os defeitos totais (soma de "gaps" e "voids") foram avaliados. Não houve diferença estatística entre os grupos em relação aos "gaps" marginais (P≥ 0,05), "voids" internos (P≥ 0,05), e aos defeitos totais (P≥ 0,05). A mediana (mm3) e porcentagem dos defeitos totais de aprisionamento de ar foi 0,004mm3 e 1,749% para o MTA Angelus, 0,018mm3 e 6,660% para o Biodentine, e 0,012mm3 e 4,079% para o Neo MTA Plus. Todos os materiais tiveram defeitos ("gaps"e/ou "voids"). Não houve diferença entre MTA Angelus, Biodentine e Neo MTA Plus.


Subject(s)
Humans , Root Canal Filling Materials , Root Canal Obturation , Root Canal Therapy , Silicates , Calcium Compounds , X-Ray Microtomography
3.
Dent. press endod ; 10(3): 49-55, Sept-Dec.2020. Tab, Ilus
Article in English | LILACS | ID: biblio-1344785

ABSTRACT

Objetivo: O presente estudo usou micro-CT para avaliar a quantidade de material obturador remanescente em canais radiculares curvos que tinham sido obturados com cimento Endosequence BC/Cpoint ou com cimento AH/ guta-percha, depois do retratamento utilizando instrumentos rotatórios ou reciprocantes. Métodos: Sessenta canais mesiovestibulares de molares superiores foram instrumentados até MTwo #35.04. As amostras foram randomicamente alocadas em quatro grupos (n=15): os canais do G1 e G2 foram obturados com AH/guta-percha, e os canais do G3 e G4 foram obturados com BC/Cpoint. O material obturador foi removido usando instrumentos rotatórios ou reciprocantes ­ G1 e G3: R25 Reciproc + reinstrumentação com R40; e G2 e G4: Sistema ProTaper Universal Retratamento + reinstrumentação com MTwo 40.06. Micro-CTs foram usadas para medir a quantidade de material obturador remanescente (mm3 ) para o canal inteiro e para cada terço, em dois momentos: 1) após a remoção do material obturador; e 2) após a reinstrumentação. Resultados: Após a remoção do material obturador, BC/CPoint permaneceu mais dentro do canal do que AH/guta-percha quando o canal inteiro (29,92% x 19,25%, p=0,0290) e o terço apical foram analisados. Após a reinstrumentação, BC/CPoint permaneceu mais do que AH/guta-percha somente no terço apical. Protocolos de tratamento com instrumentos rotatórios ou reciprocantes removeram material obturador sem diferença para AH/guta-percha (G1 e G2: p> 0,05) e BC/CPoint (G3 e G4: p> 0,05). Conclusões: BC/Cpoint é mais difícil de ser removido de canais radiculares curvos do que AH/guta-percha. Instrumentos rotatórios e reciprocantes têm habilidade similar na remoção de material obturador (AU).


Objective: This study used micro-CT to evaluate the amount of remaining filling material in curved root canals obturated with Endosequence BC Sealer/Cpoint or AH/gutta-percha after a rotary or reciprocating retreatment. Methods: Sixty mesiobuccal canals of maxillary molars were instrumented up to MTwo #35.04. Samples were randomly assigned to four groups (n=15): canals from G1 and G2 were filled with AH/gutta-percha, and canals from G3 and G4 were filled with BC/Cpoint. Filling material was removed using rotary or reciprocating instruments: G1 and G3: R25 Reciproc + re-shaping with R40; and G2 and G4: ProTaper Universal Retreatment system + re-shaping with MTwo 40.06. Micro-CT was used to measure the remaining amount of filling material (mm3 ), for the whole canal, and for each third, in two moments: 1) after filling removal and 2) after canal re-shaping. Results: After filling removal, BC/CPoint remained more into the canal than AH/Gutta-percha when the whole canal (29.92% x 19.25%, p = 0.0290) and the apical third were analyzed. After re-shaping, BC/CPoint remained more than AH/Gutta-percha only in the apical third. Rotary or reciprocating retreatment protocols removed filling material without difference for AH/gutta-percha (G1 and G2: p > 0.05) and BC/CPoint (G3 and G4: p > 0.05). Conclusion: BC/Cpoint is more difficult to be removed from curved root canals than AH/gutta-percha. Reciprocating and rotary instruments have similar ability to remove filling material (AU).


Subject(s)
Root Canal Filling Materials , Biofilms , Dental Instruments , X-Ray Microtomography , Lifting , Retreatment , Gutta-Percha , Molar
4.
Braz. dent. j ; 29(2): 189-194, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-951539

ABSTRACT

Abstract This study investigated the effect of blood-contamination on the push-out bond strength of BiodentineTM (BD) and MTA Angelus® (MTA-A) to root dentin over time. Twenty-five teeth were sectioned horizontally to obtain 120 root slices. The lumens were filled with MTA-A or BD: 60 for each cement (30 uncontaminated and 30 blood contaminated). Push out bond strength to dentin was assessed at 24 h (n=10), 7 days (n=10) and 28 days (n=10). Failure modes were classified as: cohesive, adhesive or mixed failure. Two-way ANOVA was used to investigate the interaction between blood contamination vs. hydration period. Mann Whitney test compared different materials in each period, and it also compared the contaminated versus uncontaminated material for each period. Friedman, followed by Dunn`s test, compared periods of hydration for each material, regardless of blood contamination. Failure modes were reported descriptively. The interaction hydration period vs. blood contamination was highly significant for MTA-A (P=0.001) and it was not significant for BD (P=0.474). There were no differences between bond strength of uncontaminated and contaminated BD in any of the periods. Bond strength of uncontaminated MTA-A increased at each time of hydration; but it remained stable over time for blood-contaminated samples. BD had higher bond strength than MTA-A in all periods of hydration. Cohesive failure predominated. Only for MTA-A, the over time bond strength to dentin was affected by blood contamination.


Resumo Este estudo investigou o efeito da contaminação sanguínea na resistência de união do BiodentineTM (BD) e do MTA Angelus® (MTA-A) à dentina, em diferentes períodos. Vinte e cinco dentes foram seccionados para obter 120 fatias de dentina. Os lúmens das fatias foram preenchidos com MTA-A ou BD: 60 para cada cimento (30 não-contaminados e 30 contaminados com sangue). A resistência de união à dentina foi medida por teste push-out em 24 horas (n=10), 7 dias (n=10) e 28 dias (n=10). Os tipos de falha foram classificados como: falha coesiva, adesiva ou mista. Two-way ANOVA foi usado para investigar a interação entre contaminação sanguínea vs. período de hidratação. O teste de Mann Whitney comparou os diferentes materiais em cada período, e comparou as amostras contaminadas e não contaminadas de cada material em cada tempo. O teste de Friedman, seguido pelo teste de Dunn, comparou os períodos de hidratação de cada material, independentemente da contaminação. A análise estatística mostrou a interação entre contaminação sanguínea vs. período de hidratação. Os tipos de falha foram reportados de maneira descritiva. A interação entre contaminação sanguínea vs. período de hidratação foi altamente significativa para o MTA-A (P=0,001), e não foi significativa para o BD (P=0,474). Não houve diferenças entre a resistência de união entre o BD contaminado e não-contaminado independente do período. A resistência de união do MTA-A não-contaminado aumentou a cada tempo de hidratação; mas, permaneceu estável ao longo do tempo para as amostras contaminadas com sangue. BD obteve maior resistência de união que o MTA-A em todos os períodos de hidratação. Falhas coesivas predominaram. A contaminação ao longo do tempo influenciou a resistência de união no grupo MTA-A.


Subject(s)
Humans , Blood , Materials Testing , Dentin-Bonding Agents/chemistry , Calcium Compounds/chemistry , Aluminum Compounds/chemistry , Dental Cements/chemistry , Oxides/chemistry , Silicates/chemistry , Dental Stress Analysis , Drug Combinations
5.
Dent. press endod ; 5(2): 12-19, maio-aug. 2015. ilus
Article in Portuguese | LILACS | ID: lil-775296

ABSTRACT

Investigou-se o efeito da irrigação endodôntica, com ou sem a ativação por ultrassom, na limpeza e descontaminação dos três terços do canal radicular. Dentes foram inoculados com E. faecalis e permaneceram em cultura por 50 dias, para a formação do biofilme. Os dentes foram divididos em oito grupos de acordo com o irrigante endodôntico e o uso da ativação ultrassônica: G1 = NaOCl a 2,5% + ultrassom; G2 = clorexidina solução a 2% + ultrassom; G3 = clorexidina gel a 2% + ultrassom; G4 = H2O + ultrassom; G5 = NaOCl a 2,5%; G6 = clorexidina solução a 2%; G7 = clorexidina gel a 2% e G8 = H2O. As raízes foram clivadas e analisadas por microscopia eletrônica de varredura (MEV). As imagens foram classificadas de acordo com o nível de limpeza (presença de smear layer , 2.000x) e descontaminação (presença de bactérias, 10.000x) nos terços coronário, médio e apical. O ultrassom melhorou a habilidade de limpeza e descontaminação de todos os irrigantes endodônticos testados, principalmente do hipoclorito de sódio e da clorexidina solução. A clorexidina gel sem ultrassom teve os mais baixos valores de limpeza, contudo, seu uso combinado com o ultrassom promoveu limpeza similar ao NaOCl a 2,5%. Quanto à descontaminação, no terço apical, a clorexidina solução sem ultrassom apresentou melhores resultados do que a clorexidina gel com ultrassom. O ultrassom melhorou a habilidade de limpeza nos três terços do canal radicular, por levar o irrigante em contato com os microrganismos e debris dentinários dentro do sistema de canal, otimizando a remoção desses.


Subject(s)
Chlorhexidine , Endodontics , Microscopy, Electron, Scanning , Root Canal Filling Materials , Root Canal Therapy , Sodium Hypochlorite , Therapeutic Irrigation , Ultrasonography
6.
RSBO (Impr.) ; 12(2): 166-171, Apr.-Jun. 2015.
Article in English | LILACS | ID: lil-792039

ABSTRACT

Introduction: The study aimed to explore the profile of articles published on pulp revascularization by a bibliometric analysis. Material and methods: A search was conducted on the PubMed database and studies were independently categorized according to: (i) year of publication; (ii) country where the study was conducted; (iii) study design; (iv) main topic addressed; (v) main conclusion of the article; and (vi) clinical application/other results. Findings were reported descriptively. There was not restriction regarding to initial date and the established final date was December 2014. Results: 133 studies were found; but only 86 articles were included. The most of them was published recently (23.2% in 2014) and were conducted in 24 different countries. The most frequent study design was case report (37.2%), followed by narrative reviews (16.2%). The main topic addressed was the radiographic outcomes (38.3%) and tissue engineering (19.7%). Some of the articles point the clinical application of their results. Conclusion: Most of the publications highlight that the disinfection of the root canal (and the stimulation of residual stem cells) would induce formation of new hard tissue on the dentin wall and continue root development in length, improving the tooth survival. The number of publications on pulp revascularization has increased recently, but the majority of articles published are studies with low levels of evidence.

7.
RFO UPF ; 18(3): 302-306, set.-dez. 2013. tab
Article in Portuguese | LILACS-Express | LILACS | ID: lil-726477

ABSTRACT

Objetivo: este estudo objetivou investigar se a análise da radiografia prévia pelo operador influencia no de-sempenho do localizador apical eletrônico MiniApex® no momento da mensuração do comprimento de traba-lho em dentes com fratura radicular apical. Materiais e método: vinte pré-molares inferiores unirradiculares foram randomicamente divididos em dois grupos: GA ? dentes com raiz íntegra e GB ? dentes com fratura horizontal simulada no terço apical. O comprimento de trabalho foi determinado de forma visual (CTvisu-al) reduzindo-se 1 mm do comprimento total do dente (GA) ou da linha da fratura (GB). Um único operador realizou as medidas eletrônicas do comprimento de trabalho (CTeletrônico), utilizando a marca de 0.5 no display do aparelho. Para ambos os grupos, as medidas eletrônicas foram realizadas em fases distintas: fase I ? sem análise da radiografia prévia e fase II ? com análise da radiografia prévia (medindo-se com régua milimetra-da o comprimento aparente de trabalho). O desempe-nho do localizador apical foi investigado por meio da comparação de cada medida do CTeletrônico com o CTvisual; utilizando-se, para análise dos dados, o teste t de Student. Resultados: para o GA, não houve diferença estatística em relação ao desempenho do localizador tanto para a fase I (p = 0,619) como para a fase II (p = 0,177). Para o GB houve diferença estatística para a fase I (p = 0,003), mas não para a fase II (p = 0,489). Conclu-são: a análise da radiografia prévia pelo operador, fator indispensável na prática clínica, melhorou o desempe-nho do localizador eletrônico apical MiniApex® durante a mensuração do comprimento de trabalho em dentes extraídos com fratura radicular apical simulada.

8.
RFO UPF ; 17(3)set.-dez. 2012.
Article in Portuguese | LILACS | ID: lil-683504

ABSTRACT

Objetivos: Descrever o perfil do estudante de odontologia de uma universidade do sul do Brasil, em dois momentos, isto é, no início e no término da faculdade. Métodos: Esta pesquisa com delineamento transversal, realizada no segundo semestre de 2011, avaliou, tendo como inspiração as questões do Exame Nacional de Desempenho dos Estudantes (Enade), o possível ganho de conhecimento geral e específico dos alunos iniciantes e concluintes da Faculdade de Odontologia da Universidade de Passo Fundo (UPF). Um questionário, abrangendo questões de múltipla escolha retiradas das provas do Enade ? Odontologia 2004, 2007 e 2010, foi aplicado para uma turma de estudantes iniciantes (1°semestre do curso) e para uma turma de estudantes concluintes (último ano do curso). Todos os estudantes da turma de iniciantes e da turma de concluintes foram convidados a participar. O total de respondentes foi 65 alunos, sendo 33 iniciantes e 32 concluintes. O questionário foi composto de questões socioeconômicas, conhecimento geral e conhecimento específico (odontologia), que foram analisadas por meio de porcentagens. Resultados: Observou-se que houve acréscimo de conhecimento geral e específico na formação do estudante: o número total de acertos para iniciantes foi n = 83, e para concluintes, n = 163. Conclusão: Foi sugerido que os estudantes do curso de Odontologia da UPF estão agregando conhecimento humano e ético à sua formação, além do conhecimento técnico-científico.

9.
Braz. oral res ; 26(2): 106-111, Mar.-Apr. 2012. tab
Article in English | LILACS | ID: lil-622916

ABSTRACT

The aim of this study was to assess, in vivo, the accuracy of the NovApex® electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex®was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex® locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex®(a = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex® measurement. Pulp condition had no significant effect on the accuracy of NovApex®.


Subject(s)
Adolescent , Adult , Aged , Humans , Middle Aged , Young Adult , Dental Pulp Cavity/anatomy & histology , Dental Pulp/pathology , Root Canal Preparation/instrumentation , Tooth Apex/anatomy & histology , Chi-Square Distribution , Dental Instruments , Dental Pulp Cavity , Dental Pulp Necrosis/pathology , Dental Pulp Necrosis , Dental Pulp , Electronics, Medical/instrumentation , Organ Size , Odontometry/instrumentation , Reproducibility of Results , Tooth Apex
10.
Rev. odonto ciênc ; 27(3): 208-212, 2012. ilus, tab
Article in English | LILACS, BBO | ID: lil-656786

ABSTRACT

PURPOSE: To evaluate the ability sealing of glass ionomer and composite resin with or without 1-mm thickness of Coltosol on the root-canal filling material. METHODS: Root-canal treatment was completed on 50-extracted human mandibular unirradicular. The teeth were divided into six groups: G1, positive control; G2, negative control; G3, glass ionomer (Vidrion R); G4, Coltosol + Vidrion R; G5, composite resin; and, G6, Coltosol + composite resin. For G1 and G2 five teeth each were used and for the other groups, ten teeth each. The teeth were thermocycled and evaluated for microleakage using methylene blue dye. Specimens were sectioned and measurements made to the maximum point of dye penetration. The mean dye penetration (%) for each group was compared by ANOVA and Tukey's test for post-hoc comparisons (α=0.05). RESULTS: The means and standard deviations of microleakage were: G1, 96.56 (±2.31); G2, 0.00 (±0.00); G3, 68.76 (±24.63); G4, 24.42 (±8.33); G5, 20.06 (±9.35); and, G6, 12.86 (±6.08). CONCLUSION: It was concluded that none of the materials were able to prevent microleakage. Composite resin alone or combined with coltosol and glass ionomer associated with coltosol resulted in less microleakage than the glass ionomer used alone.


OBJETIVOS: Avaliar a capacidade de selamento do ionomero de vidro e resina composta, com ou sem 1 mm de coltosol, sobre o material obturador endodôntico. MÉTODOS: O tratamento endodôntico foi realizado em 50 dentes humanos mandibulares unirradiculares. Os dentes foram divididos em 6 grupos: G1, controle positivo; G2, controle negativo; G3, ionômero de vidro (Vidrion R); G4, Coltosol + Vidrion R; G5, resina composta; e, G6, Coltosol + resina composta. Os dentes foram submetidos a termociclagem e a avaliação da microinfiltração usando azul de metileno. Os especimes foram seccionados e a quantidade maxima de penetração de corante avaliado. As medias e desvios-padrão de penetração do corante (em %) para cada grupo foram analisadas pelo teste ANOVA e pelo teste de multiplas comparações de Tukey's (α=0.05). RESULTADOS: As medias e desvios-padrão de midroinfiltração foram: G1: 96,56 (±2,31); G2: 0,00 (±0,00); G3: 68,76 (±24,63); G4: 24,42 (±8,33); G5: 20,06 (±9,35); and,G6: 12,86 (±6,08). CONCLUSÃO: Pode-se concluir que nenhum material obturador preveniu completamente a microinfiltração. Resina composta utilizada isoladamente ou associada ao coltosol e o ionômero de vidro associado ao coltosol apresentaram menor microinfiltração do que o ionomero de vidro utilizado sozinho.


Subject(s)
Humans , Male , Female , Glass Ionomer Cements , Root Canal Filling Materials , Composite Resins
11.
RSBO (Impr.) ; 8(1): 48-53, jan.-mar. 2011. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-874405

ABSTRACT

Introdução e objetivo: Este estudo in vitro verificou por meio de microscopia eletrônica de varredura (MEV) alterações estruturais no vidro quando em contato com o ácido etilenodiaminotetracético (EDTA). Material e métodos: A metade inferior de quatro lamínulas de vidro permaneceu submersa em EDTA 17%, pH 7,3, por diferentes tempos (7 dias, 24 horas, 6 horas e 30 minutos). Como controle, examinou-se uma amostra que ficou parcialmente imersa em água destilada por 24 horas. As amostras foram analisadas em MEV e fotografadas com magnitudes de 19, 50, 100, 200, 400, 1.000, 2.000 e 3.000 vezes. Resultados: Constatou-se que nas quatro lamínulas que estiveram em contato com o EDTA houve formação de bolhas e rachaduras no vidro, independentemente do tempo testado. A amostra controle apresentou poucos defeitos no vidro e diferenciou-se das que ficaram em contato com a substância. Conclusão: O EDTA provocou alterações na estrutura do vidro.


Introduction and objective: This in vitro study verified, through SEM, the structural changes on glass surface when submitted to EDTA. Material and methods: Samples of 4 glass coverslip remained partially (lower half of the sample) immersed in 17% EDTA pH 7.3 for different periods (7 days, 24 hours, 6 hours and 30 minutes). The samples were analyzed by SEM and photographed with x19, 50, 100, 200, 400, 1000, 2000, and 3000 magnification. Results: It was found that the four glass samples submitted to EDTA showed blisters and cracks regardless of time. The control sample showed few defects differing from those in contact with EDTA. Conclusion: EDTA led to changes in the glass structure.


Subject(s)
In Vitro Techniques , Smear Layer , Dental Pulp Cavity , Microscopy, Electron, Scanning , Chelating Agents , Glass , Edetic Acid
12.
Braz. dent. j ; 22(3): 218-222, 2011. ilus, tab
Article in English | LILACS | ID: lil-595651

ABSTRACT

This study used a mechanical test to evaluate the flexibility of instruments from the K3 (conicity 0.04) and the ProTaper Universal systems when they were new and after 5 uses in simulated canals. Five sets of instruments of each system were tested: K3 (15, 20, 25, 30, 35, 40 and 45) and ProTaper Universal (S1, S2, F1, F2, F3, F4 and F5). Each set of instruments was used to prepare a simulated canal and the same set of instruments was used 5 times (50 canals). The number of each subgroup represented the number of uses: 0 (control), 1, 3 and 5 uses. Before and after each use, the instruments were submitted to a mechanical flexibility test performed in a Versat 502 universal testing machine. Interactions between the instrument and the number of uses were analyzed by ANOVA and Tukey's test at a 5 percent level of significance. Instruments from both systems presented lower flexibility after the third use compared to the flexibility obtained after uses 0 and 1 (p<0.05), and maintained the same flexibility after the fifth use. The flexibility of instruments from the K3 system decreased with the increase of diameter, irrespective of the number of uses. Among the instruments from the ProTaper Universal system, the shaping files presented greater flexibility than the finishing files. F2 and F3 were the least flexible instruments, and F4 and F5 presented flexibility values similar to those of F1.


Esta pesquisa estudou a flexibilidade de instrumentos do Sistema K3 (conicidade 0.04) e do Sistema ProTaper Universal, por meio de um teste mecânico, quando os instrumentos eram novos e após 5 usos em canais simulados. Cinco jogos de instrumentos de cada sistema foram testados, como segue: grupo I - K3 (15, 20, 25, 30, 35, 40 e 45), e grupo II - ProTaper Universal (S1, S2, F1, F2, F3, F4 e F5). Cada jogo de instrumento foi usado para preparar um canal simulado, e o mesmo jogo de instrumento foi usado 5 vezes (50 canais). O número de cada subgrupo representou o número de usos: 0 (controle), 1, 3 e 5 usos. Antes do uso e depois de cada uso os instrumentos foram submetidos a um teste mecânico de flexibilidade realizado na máquina de ensaios universais Versat 502. A interação entre o instrumento e o número de usos foi analisada pelo ANOVA e pelo teste de Tukey ao nível de significância 5 por cento. Instrumentos de ambos os sistemas apresentaram menor flexibilidade após o terceiro uso quando comparada com a flexibilidade após os usos 0 e 1 (p<0,05), e mantiveram a mesma flexibilidade após o quinto uso. A flexibilidade dos instrumentos do sistema K3 diminuiu conforme o aumento de diâmetro, independente do número de usos. Entre os instrumentos do sistema ProTaper Universal, os shaping apresentaram maior flexibilidade que os finishing. F2 e F3 foram os menos flexíveis e F4 e F5 apresentaram valores de flexibilidade similares ao F1.


Subject(s)
Humans , Dental Alloys/chemistry , Nickel/chemistry , Root Canal Preparation/instrumentation , Titanium/chemistry , Dental Pulp Cavity/anatomy & histology , Dental Stress Analysis/instrumentation , Elastic Modulus , Epoxy Resins , Equipment Reuse , Materials Testing , Models, Anatomic , Pliability , Stress, Mechanical , Surface Properties
13.
Rev. odonto ciênc ; 26(2): 121-125, 2011. tab
Article in English | LILACS, BBO | ID: lil-611657

ABSTRACT

PURPOSE: In Brazil, the SINAES is a process that is currently used to assess higher education institutions, undergraduate programs and students' performance on the ENADE national exam. This study aimed at assessing the Brazilian undergraduate programs in Dentistry, inquiring if the evaluation results induced to changes to improve the teaching-learning process. METHODS: This cross-sectional study utilized a questionnaire that was e-mailed to 165 professors/coordinators of undergraduate programs in Dentistry in Brazil in 2003/2004. The data analysis was based on the themes of the various open- and closed-ended questions: questions 1, 2, 3 and 4 referred to the evaluation of each institution and its undergraduate program, whereas questions 5, 6 and 7 referred to the ENADE. RESULTS: Changes to improve the quality of teaching in Dentistry and the education of new professionals were driven by the results of the evaluation. These changes were implemented at all institutions that returned the completed questionnaires. CONCLUSION: Improvements in the quality of Brazilian Dentistry will only be possible if the education of the students and the professors is improved.


OBJETIVO: No Brasil, o SINAES é a proposta de avaliação da educação superior atualmente em vigência e que avalia as instituições de educação superior, os cursos de graduação e o desempenho dos estudantes (ENADE). Este estudo abordou a avaliação dos cursos de Odontologia em 2003 e 2004 para observar se os resultados da avaliação induziram melhora no processo ensino-aprendizagem. METODOLOGIA: Este estudo transversal foi realizado por meio de questionários com questões abertas e fechadas enviados por e-mail a 165 professores/coordenadores dos programas de graduação em Odontologia do Brasil em 2003/2004. As questões 1, 2 e 3 se referiram à avaliação das Instituições e dos cursos de Odontologia. As questões 5, 6 e 7 se referiram ao ENADE. RESULTADOS: As mudanças com objetivo de melhora na qualidade do ensino em Odontologia e na educação de novos profissionais são impulsionadas pelos resultados do processo de avaliação. Tais mudanças foram implementadas em todas as Instituições de ensino que retornaram os questionários preenchidos. CONCLUSÃO: Mudanças na qualidade da Odontologia brasileira somente serão possíveis se ocorrer melhora no processo educativo de estudantes e professores.


Subject(s)
Educational Measurement , Universities , Education, Dental , Brazil , Surveys and Questionnaires
14.
Stomatos ; 16(31): 45-54, jun.-dez. 2010. tab
Article in Portuguese | LILACS, BBO | ID: lil-693945

ABSTRACT

O objetivo deste trabalho foi avaliar a atividade antimicrobiana do paramonoclorofenol canforado (PMCC), por contato direto e vapor contra o Enterococcus faecalis e Staphylococcus aureus. O método empregado foi o de difusão em ágar. Utilizaram-se dez dentes humanos extraidos (caninos superiores e inferiores, pré-molares superiores e inferiores), que foram transfixados a placas de Petry com resina acrílica auto-polimerizável, de forma que as coroas dentais ficassem acima da tampa destas placas. Ao redor dos ápices radiculares foi colado um cilindro de vidro de, aproximadamente, 5mm de diâmetro e 1,5 cm de altura. O teste por contato direto foi realizado com discos de papel filtro embebidos em 3µL de PMCC colocados diretamente sobre o meio de cultura inoculado com os microrganismos. Para o teste por vapor, o PMCC foi levado ao interior do canal com um cone de papel absorvente #40, onde permaneceu por 24 horas. Os resultados revelaram que o medicamento apresentou efeito antimicrobiano após contato direto com as culturas, formando halos de inibição bacteriana. Em relação aos vapores liberados pelo produto, pôde-se constatar que não houve nenhuma ação por vapor quando o fármaco esteve no canal radicular, pois houve crescimento bacteriano próximo a região do ápice radicular.


The aim of this study was to evaluate antibacterial activity of the canphorated paramonochorophenol (PMCC) by direct contact and vapor against Enterococcus faecalis and Staphylococcus aureus. The test of agar difusion was the method used. It were used human extracted teeth (maxillary and mandibulary canines and maxillary and mandibulary pre-molars) that were fixed on Petri slabs by acrylic resin in order to keep the tooth crown above of the slab cover. A glass cylinder (5 mm of diameter and 1,5 cm of height) was fixed around the root apex was fixed. The direct contact test was realized by papers disks were soaked with PMCC (3 µL) that put directly in contact with the agar. For the steam test, we put a paper point into canal root soaked with PMCC (3µL) that remained per 24 hours. The results showed that the PMCC was effective against micoorganisms when in direct contact with them, with zones of bacterial inhibition. Regarding the release of vapor by PMCC into de canal root, there was no any reaction, because there was bacterial growth.


Subject(s)
Chlorophenols , Camphor/administration & dosage , Camphor/therapeutic use , Endodontics , Enterococcus faecalis , Dental Materials , Staphylococcus aureus , Materials Testing , Root Canal Therapy
15.
Stomatos ; 16(31): 69-76, jun.-dez. 2010. graf, tab
Article in Portuguese | LILACS, BBO | ID: lil-693947

ABSTRACT

A reunião anual da Sociedade Brasileira de Pesquisa Odontológica (SBPqO) é um evento representativo para a divulgação das pesquisas cientificas na área de odontologia realizadas no Brasil. O objetivo do presente trabalho foi realizar o levantamento das publicações realizadas pelo corpo docente e discente do Curso de Odontologia da Universidade Luterana do Brasil/ULBRA (Campus Canoas, Cachoeira do Sul e Torres) nos Suplementos da Brazilian Oral Research, periódico científico oriundo das apresentações dos painéis na SBPqO. Para isso, os resumos publicados foram acessados por meio de consulta on line no site da instituição e catalogados conforme o ano da reunião, o código da pesquisa, os autores (por sobrenome), a categoria do painel e o delineamento do estudo. Os dados foram transferidos para uma tabela a partir da primeira publicação e analisados em relação ao número de publicações/ano e quanto ao delineamento do estudo. O ano de 2006 apresentou o maior número de publicações (50), entretanto a produtividade apresenta-se em declínio nos últimos três anos (2007, 2008 e 2009). O delineamento da maioria das pesquisas no período analisado são laboratoriais (in vitro) e transversais, ou seja, estudos com baixo poder de gerar evidência científica.


The Brazilian Society for Dental Research (SBPqO) is an annual meeting for the publishing of the dentistry scientific research in Brazil. The aim of this study was to search publications by students and professors of School of Dentistry, Lutheran University of Brazil / ULBRA (Canoas, Cachoeira do Sul, Torres) in the Brazilian Oral Supplements Research, a scientific journal dedicated to publication of SBPqO research banners. Published abstracts were accessed by online searching on site of SBPqO and organized according to: year, code research, authors (surname), banner category and the study design. Data were organized in a table from the first publication and analyzed in relation to the frequency of publications per year and study design. In 2006 there was the highest number of publications (50). However, the publications are decreasing on last three years (2007, 2008 e 2009). The design of most publications at period was in vitro and cross-sectional. These studies have low capacity to generate scientific evidence.


Subject(s)
Cross-Sectional Studies , Dentistry , Scientific and Technical Publications
16.
Braz. oral res ; 24(3): 271-276, July-Sept. 2010. tab
Article in English | LILACS | ID: lil-558738

ABSTRACT

This in vitro study evaluated (1) the dissolution of bovine pulp tissue in solutions consisting of varying NaOCl concentrations and combined with EDTA; and (2) the pH of these solutions before and after the experiment. The independent variables were the concentration and the volume of the solution. Thirty bovine pulps were divided in equal fragments, resulting in 90 fragments of pulp tissue. Each fragment was immersed in one of the following solutions: 1 percent NaOCl (4 ml), 2.5 percent NaOCl (4 ml), 1 percent NaOCl + 17 percent EDTA (2 ml : 2 ml), 1 percent NaOCl + 17 percent EDTA (1 ml : 3 ml), 2.5 percent NaOCl + 17 percent EDTA (2 ml : 2 ml), and 2.5 percent NaOCl + 17 percent EDTA (1 ml : 3 ml). The test solutions were dichotomized as either able or not able to dissolve the tissue, the latter being attributed when the dissolution of the pulp tissue was not complete within 48 hours. When the samples were able to dissolve the tissue, the time required for complete tissue dissolution was submitted to statistical analysis. The pH of the solutions was measured before and after the experiment. The pH variable was dichotomized as either changed or unchanged. The results demonstrated that the NaOCl solutions combined with 17 percent EDTA were not able to dissolve the tissue. The t-test revealed that the 2.5 percent NaOCl solution presented a lower mean dissolution time than the 1 percent NaOCl solution (p < 0.001). The pH of the solutions with equal volumes of NaOCl and EDTA decreased in 48 hours.


Subject(s)
Animals , Cattle , Dental Pulp/drug effects , Disinfectants/chemistry , Edetic Acid/chemistry , Root Canal Irrigants/administration & dosage , Sodium Hypochlorite/chemistry , Dental Pulp/chemistry , Disinfectants/pharmacology , Edetic Acid/pharmacology , Hydrogen-Ion Concentration , Root Canal Irrigants/pharmacology , Solutions , Sodium Hypochlorite/pharmacology , Time Factors
17.
RSBO (Impr.) ; 7(2): 193-199, jun. 2010.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-550995

ABSTRACT

Introdução e objetivo: A literatura carece de informações acercado possível aumento da temperatura na superfície externa radiculardurante a utilização das brocas LA Axxess. Este estudo in vitroobjetivou investigar o efeito, em relação à variação de temperatura,do diâmetro da broca LA Axxess e do tipo de movimento aplicado nopreparo cervical de canais mesiovestibulares (MV) e mesiolinguais(ML) de molares inferiores humanos extraídos. Material e métodos: Utilizaram-se 30 molares inferiores humanos extraídos que foramdivididos randomicamente em três grupos experimentais de acordocom o diâmetro da broca a ser usada: 20/.06, 35/.06 e 45/.06. Um únicooperador aplicou os seguintes movimentos durante o preparo cervicalnas amostras: 1) movimento contínuo no canal MV; 2) movimentointermitente no canal ML. Cada movimento teve duração de 5 segundos.A variação de temperatura foi medida por um termopar fixado na raize acoplado a um termômetro digital. Os valores correspondentes àvariação de temperatura foram submetidos a análise estatística pormeio da Análise de Variância (Anova) com nível de significância de5% em relação às variáveis independentes: diâmetro da broca e tipode movimento. Resultados: O diâmetro da broca não influenciou noaumento de temperatura. O movimento contínuo apresentou umaelevação significativa na temperatura externa radicular em relação aomovimento intermitente. Conclusão: O emprego das brocas LA Axxess,durante 5 segundos no preparo cervical, é seguro em relação ao aumentode temperatura, independentemente do diâmetro da broca e do tipo demovimento aplicado.


Introduction and objective: There is very little information on thescientific literature regarding the temperature rise on the outer rootsurface during cervical preparation using LA Axxess burs. The aim ofthis in vitro study was to investigate the effect, regarding the temperaturevariation, of the diameter of the LA Axxess bur and the type of movementapplied during cervical preparation of mesiobuccal (MB) and mesiolingual(ML) root canals of extracted mandibular human molars. Material andmethods: 30 extracted mandibular human molars were randomlydivided into three experimental groups according to the diameter ofthe bur to be used: 20/.06, 35/.06 and 45./06. A single operator appliedthe following movements on the samples during cervical preparation:1) continuous movement in the MB root canal; 2) intermittent movementin the ML root canal. Each movement lasted 5 seconds. Temperaturevariation was measured by a thermocouple fixed on the root andconnected to a digital thermometer. Variation temperature data wasanalyzed through ANOVA test with significance level of 5% in relation tothe independent variables: diameter of the bur and type of movement.Results: The diameter of the bur did not influence on the temperaturerise. The continuous movement showed a higher significant rise on theouter root temperature than the intermittent movement. Conclusion:The use of LA Axxess burs on cervical preparation during 5 seconds issafe in relation to the temperature rise regardless the diameter of thebur and the type of movement applied.

18.
J. appl. oral sci ; 17(5): 501-507, Sept.-Oct. 2009. ilus, tab
Article in English | LILACS | ID: lil-531404

ABSTRACT

OBJECTIVE: This study evaluated the wear in the apical third of simulate canals after preparation with ProTaper Universal Rotary System. MATERIAL AND METHODS: 24 sets of instruments were used in 24 simulated canals in transparent epoxy resin blocks with degree of curvature of either 20°or 40°. The canals were photographed preoperatively and after preparation of the apical stop with ProTaper F3, F4 and F5 instruments. The initial and final images were exported to Adobe Photoshop® software and superimposed to detect the root canal wall differences (in mm) between them, in two points located 1 (A) and 5 (B) mm from the point where the working length was established. Data were subjected to analysis of variance to verify the existence of interaction among the factors: canal curvature, instrument size and curve location. Significant level was set at 5 percent. RESULTS: Regardless of the location and the canal curvature, F4 and F5 instruments produced the greatest wear (p<0.05). CONCLUSIONS: There was a deviation from the original pathway towards the outside of the root curvature in both analyzed points. All instruments produced canal transportation, but the F4 and F5 instruments produced more than the other instruments, and should thus be used with care in curved canals.


Subject(s)
Humans , Dental Pulp Cavity/anatomy & histology , Root Canal Preparation/instrumentation , Tooth Apex/anatomy & histology , Dental Alloys , Detergents/therapeutic use , Epoxy Resins , Equipment Design , Image Processing, Computer-Assisted , Models, Anatomic , Root Canal Irrigants/therapeutic use , Root Canal Preparation/methods , Software , Stainless Steel , Surface Properties , Sodium Dodecyl Sulfate/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL